Follow
CAMBI Research Center
CAMBI Research Center
Advanced Research Center for Ambiental Quality and Building Physics
Verified email at cambi.ro
Title
Cited by
Cited by
Year
Development and validation of regression models to predict monthly heating demand for residential buildings
T Catalina, J Virgone, E Blanco
Energy and buildings 40 (10), 1825-1832, 2008
3642008
Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling
T Catalina, J Virgone, F Kuznik
Building and environment 44 (8), 1740-1750, 2009
2672009
Multiple regression model for fast prediction of the heating energy demand
T Catalina, V Iordache, B Caracaleanu
Energy and buildings 57, 302-312, 2013
2482013
Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools
O Poupard, P Blondeau, V Iordache, F Allard
Atmospheric Environment 39 (11), 2071-2080, 2005
1562005
Thermal comfort models for indoor spaces and vehicles—Current capabilities and future perspectives
C Croitoru, I Nastase, F Bode, A Meslem, A Dogeanu
Renewable and Sustainable Energy Reviews 44, 304-318, 2015
1252015
IEQ assessment on schools in the design stage
T Catalina, V Iordache
Building and Environment 49, 129-140, 2012
1242012
Assessment of contaminant diffusivities in building materials from porosimetry tests.
P Blondeau, AL Tiffonnet, A Damian, O Amiri, JL Molina
Indoor air 13 (3), 310-318, 2003
1142003
Multi-source energy systems analysis using a multi-criteria decision aid methodology
T Catalina, J Virgone, E Blanco
Renewable Energy 36 (8), 2245-2252, 2011
842011
Study on the impact of the building form on the energy consumption
T Catalina, J Virgone, V Iordache
Proceedings of building simulation, 1726-1729, 2011
832011
Vortex dynamics and mass entrainment in turbulent lobed jets with and without lobe deflection angles
I Nastase, A Meslem
Experiments in fluids 48 (4), 693-714, 2010
822010
Primary and secondary vortical structures contribution in the entrainment of low Reynolds number jet flows
I Nastase, A Meslem, P Gervais
Experiments in Fluids 44 (6), 1027-1033, 2008
782008
Passive mixing control for innovative air diffusion terminal devices for buildings
A Meslem, I Nastase, F Allard
Building and Environment 45 (12), 2679-2688, 2010
762010
Determining the indoor environment quality for an educational building
T Mihai, V Iordache
Energy Procedia 85, 566-574, 2016
682016
Lobed grilles for high mixing ventilation–An experimental analysis in a full scale model room
I Nastase, A Meslem, I Vlad, I Colda
Building and Environment 46 (3), 547-555, 2011
672011
Energy efficiency versus indoor environmental quality in different Romanian countryside schools
SA Ghita, T Catalina
Energy and Buildings 92, 140-154, 2015
582015
Wall shear rates and mass transfer in impinging jets: Comparison of circular convergent and cross-shaped orifice nozzles
M Kristiawan, A Meslem, I Nastase, V Sobolik
International Journal of Heat and Mass Transfer 55 (1-3), 282-293, 2012
562012
Acoustic approach for building air permeability estimation
V Iordache, T Catalina
Building and Environment 57, 18-27, 2012
542012
Spectropolarimetry of cancer change of biotissues
S Yermolenko, A Ushenko, P Ivashko, F Goudail, I Gruia, C GavrilŃ, ...
Ninth International Conference on Correlation Optics 7388, 404-410, 2009
492009
Comparison of turbulence models in simulating jet flow from a cross-shaped orifice
A Meslem, F Bode, C Croitoru, I Nastase
European Journal of Mechanics-B/Fluids 44, 100-120, 2014
482014
Numerical modelling of combined heat transfers in a double skin fašade–Full-scale laboratory experiment validation
F Kuznik, T Catalina, L Gauzere, M Woloszyn, JJ Roux
Applied thermal engineering 31 (14-15), 3043-3054, 2011
482011
The system can't perform the operation now. Try again later.
Articles 1–20