Urmăriți
Bodige Narender
Bodige Narender
Anurag University
Adresă de e-mail confirmată pe anurag.edu.in
Titlu
Citat de
Citat de
Anul
2D Numerical modeling of progressive collapse during earthquakes: a case study on RC bare frame
HB Raparla, N Bodige, RP Kumar
Proceedings of international conference on advances in civil engineering, 21-23, 2011
72011
Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile Detailing, Report No: IIIT
N Bodige, PK Ramancharla
TR/2012/-1, Urban Safety of Mega Cities in Asia (USMCA), 2012
62012
Rapid visual screening for seismic evaluation of existing buildings in Himachal Pradesh
PK Ramancharla, R Chenna, SS Goud, AK Sreerama, G Vignesh, ...
Centre for Earthquake Engineering International Institute of Information …, 2014
52014
Preliminary seismic hazard map of Peninsular India
C Rajaram, B Narender, ND Satyam, PR Kumar
14SEE conference, 2010
42010
Seismic Behaviour of G+ 7 RC Open Ground Storey Buildings with Fluid Viscous Dampers
S Shayza, B Narender
Advances in Structural Engineering: Select Proceedings of FACE 2019, 205-216, 2020
32020
Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile Detailing
N Bodige, PK Ramancharla
Proceedings of the 15th World Conference on Earthquake Engineering (15WCEE), 2012
32012
A comparative study on conventional structure to steel diagrid structure with the effect of different seismic zones
SKDB Narender
Journal of Xi'an University of Architecture & Technology 13 (Issue 8, 2021 …, 2021
2021
Vulnerability assessment of a heritage structure subjected to blast-induced ground motions
RP Kumar, D Srinagesh, T Seshunarayana, RK Chadha, N Bodige, ...
Current Science 119 (7), 1131-1141, 2020
2020
Retrofit of existing open ground parking RC buildings in Hyderabad city
DBNK Tejaswini
17th world conference on earthquake engineering (17WCEE), Sendai, Japan, 2020
2020
Seismic Behavior of Mid-Rise Precast Reinforced Concrete Building with Effect of Joints and Supports
SBIDB Narender
International Journal of Recent Technology and Engineering 8 (4), 2019
2019
Seismic Fragility curves for R.C. flat slab framed buildings with and without infill
GJDB Narender
International Journal of Innovative Technology and Exploring Engineering 9 (2), 2019
2019
Seismic Fragility Curves of R.C.Framed Buildings Designed as per IS Low, Medium and High code
E.Sathish Reddy and B. Narender
International Journal of Innovative Technology and Exploring Engineering 9 (2), 2019
2019
Effect of Steel Bracing in Progressive Collapse of Multi Storey RC Buildings
IAKDB Narender
International Journal of Recent Technology and Engineering 8 (4), 2019
2019
Seismic Behavior of RC buildings with Effect of Staircase and Elevator Core Wall
AHHB Narender
International Journal of Recent Technology and Engineering 8 (4), 2019
2019
Development of fragility curve for existing soft storey RC building with varying soft storey heights using HAZUS method
ASDB Narender
International Conference on Innovative Trends in Civil Engineering for …, 2019
2019
Seismic Behavior Of Flat Slab Building With Effect Of Brick Masonry Infill
A.Naresh and Dr.Narender Bodige
National Conference On Advances in Science and Technology in Civil …, 2019
2019
Seismic retrofitting of G+6 existing structure by adding additional floors
Ahfaz Rasool, K.Harish Kumar, Dr.Narender Bodige, Dr.A.Vimala
National Conference on Advances in Frontier of Civil Engineering (NCAFCE …, 2018
2018
Assessment of capacity of existing Building Through Nonlinear Static Pushover Analysis: A Comparison between Micro an Macro Modeling
BNR Pradeep
The Indian Concrete Journla 90 (4), 33-42, 2016
2016
Earthquake Response Analysis of Buildings at The Union Territory of Chandigarh, India, by using Building Vibration Observations due to Weak Earthquake Ground Motions
K Takano, T Ito, T Masuda, K Koketsu, PK Ramancharla, R Sangam, ...
AGU Fall Meeting Abstracts 2014, S31C-4429, 2014
2014
Micro-tremor Response of Buildings in high Seismic Areas: A Case Study on RC Framed Building in Chandigarh, India Part II: Response of building
N Bodige, H Chandan, PK Ramancharla
2013
Sistemul nu poate realiza operația în acest moment. Încercați din nou mai târziu.